The NPW-series consist of valve-regulated lead-acid batteries that are specially designed for applications that require high current during a short time. NPW-batteries can deliver up to 50% more power during a short period than a corresponding NP battery thus saving both size and weight. The battery is made in 12 V blocks. Life expectancy class is up to 5 years. Order for your YUASA Battery from Jumia online and have it delivered straight to your doorstep.
image
Safety
Installation Can be installed and operated in any orientation except permanently inverted.
Handles Batteries must not be suspended by their handles (where fitted).
Vent valves Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal.
Gas release VRLA batteries release hydrogen gas which can form explosive mixtures in the air.
Do not place inside a sealed container.
Recycling YUASA’s VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations.
Specifications
Nominal voltage (V) 12
10m rate Constant Power (Typ) to 9.6V at 20°C (W/Block) 252
10m rate Constant Power (Typ) to 1.6V/cell at 20°C (W/Cell) 42
20-hr rate Capacity to 10.5V at 20°C (Ah) 8.5
10-hr rate Capacity to 10.8V at 20°C (Ah) 7.42
Terminal Type
FASTON – Quickfit / release (JST where stated) 6.35
Operating Temperature Range
Storage (in fully charged condition) -15°C to +40°C
Charge -0°C to +40°C
Discharge -15°C to +50°C
Storage
Capacity loss per month at 20°C (% approx.) 3
Case Material
Standard ABS (UL94:HB)
FR version available UL94:V0
Charge Voltage
Float charge voltage at 20°C (V)/Block 13.65 (±1%)
Float charge voltage at 20°C (V)/Cell 2.275 (±1%)
Float Chg voltage tmp correction factor from std 20°C (mV) -3
Cyclic (or Boost) charge Voltage at 20°C (V)/Block 14.5 (±3%)
Cyclic (or Boost) charge Voltage at 20°C (V)/Cell 2.42 (±3%)
Cyclic Chg voltage tmp correction factor from std 20°C (mV) -4
Charge Current
Float charge current limit (A) No limit
Cyclic (or Boost) charge current limit (A) 2.125
Maximum Discharge Current
1 second (A) 105 1 minute (A) 42
Impedance Measured at 1 kHz (mΩ) 24